The pressure switch on an air compressor is designed to safeguard the parts that comprise the machine from damage caused by excess surges of air pressure. During instances where the pressurization intensity of the air stored inside the tank reaches a level that exceeds the capacity of the air compressor, the pressure switch will suspend the activity of the compressor pump. The pressure regulator is a component that you monitor and adjust to ensure that the corresponding air tool receives proper PSI. Though you might never need to make an air compressor pressure switch adjustment, you probably will need to adjust the pressure regulator if you use an assortment of pneumatic tools.

The compressor will stop when it reaches the cut-out pressure and will start again when the pressure drops back to the cut-in pressure. You set the minimum pressure on the pressure switch at 6 bar and you set the maximum pressure at 7.1 bar. Since the cut-out pressure is defined as the cut-in pressure + the pressure differential, it’s best to first set the cut-in pressure.

Despite having such versatile uses, I found out that most people are confused about how to adjust air compressor pressure regulator. Before moving on to how to adjust air compressor regulator, it’s important to learn what a pressure regulator is and what it does. You must ensure that you adjust the air compressor pressure regulator properly to make sure the air tool psi is compatible.

Like what exactly is a pressure regulator, why it is important, how to figure out the pressure reading and lastly how to adjust the pressure of the compressor. It is possible to extract more air pressure from the compressor at hand, by turning up the pressure valve. Each air compressor has a plethora of features, and almost all of them are equipped with a pressure regulator.

Pressure switches for air compressors with already set differential usually have only one set screw that allows you to adjust the pressure. If you are still confused about how to set the PSI on your air compressor, do not be afraid to ask as it is certainly better to be safe than sorry. You can also ask for a demonstration at the store where you bought the tool for specific instructions on how to safely set PSI. So now that you know how to set the PSI, go and choose the perfect air compressor for your needs, whether it be a pancake compressor or a 12volt model, or anything else.

how to set air compressor psi Related Question:

What pressure should my air compressor be set at?

A rule of thumb is that the pressure differential of at least 1 bar (14 psi). If the difference between the cut-in pressure and the cut-out pressure is set too small, the compressor will quickly start and stop repeatedly.

What PSI should air compressor turn off?

The air compressor will continue to run until the pressure (PSI) in the air tank reaches the Max PSI (that is pre-set) and Kick Off (shut off) (example Max 120 PSI).

Can I leave air in my air compressor?

The short answer is yes, it is perfectly safe to leave an air compressor full. However, this assumes that it has been properly maintained, with regular draining to remove accumulated moisture from inside the tank.

Why do air compressors have 2 gauges?

The purpose of the two gauges is to differentiate the regulation of air pressure sent to the tank from the pressurization intensity that occurs inside the tank.

How long should an air compressor run?

2.1 states that 1.5 psi pressure loss per 24 hour period is acceptable. We recommend that a compressor cycle no more than 4 times per hour to ensure maximum compressor life, so you are in very good shape with your system.”

Why does my compressor keep running?

Reciprocating units need time to stop and cool off, or the internals will become damaged. When damage occurs, the compressor can experience valve failures, causing the compressors to run constantly. If your reciprocating compressors are never turning off, you should investigate.

Why is my air compressor building too much pressure?

Pressure restrictions often result from improper attachments or faulty machine piping. Defective piping and attachments are common in components like hoses, filters and end-use connectors, and they can cause overcompensation in the air compressor.

Is it OK to leave an air compressor pressurized?

Leaving an air compressor pressurized does not have any immediate bad effects. Most compressors are designed to tolerate pressurization for a day or two without the tank suffering a catastrophic failure. Doing so has a major drawback. A continuously pressurized tank will weaken its seal.

Can air compressor explode?

Yes, air compressors can blow up. Air compressor explosions are most commonly caused by substantial corrosion of the compressor tank. Excessive condensation leads to corrosion, and you can avoid this outcome by monitoring and servicing the compressor and its auxiliary components.

How long can you leave an air compressor full?

How long can you leave a compressor running? Depending on the size and type of compressor, air compressors can be left running anywhere from a few hours to 24 hours a day, seven days a week. Knowing your compressor and its needs and limitations is vital in keeping this invaluable equipment operating correctly.

What are the 2 dials on an air compressor?

One of them is the pressure gauge to indicate the air pressure in the tank. The other pressure gauge is the pressure gauge that indicates the pressure setting at the regulator. This pressure is the amount of pressure received by the air tool.

How do you set cut in and cut out pressure?

Adjusting the Cut-In 1. Rotate the range nut in a clockwise direction for higher cut-in pressure and counter clockwise for lower cut-in pressure. Note: changing these settings DOES NOT change the differential.

What does 75 duty cycle mean?

75% Duty Cycle Air compressors with a 75% duty cycle will run for three-fourths of the total cycle time. In other words, if a compressor has a 60-second cycle time, it will run pressurized air for 45 seconds of each minute.

How long does it take for air compressor to build pressure?

It takes 2.5 minutes to get full pressure. Tools are guaranteed to work at 90, so don’t operate tools over 100psi.

What is a 100% duty cycle?

A 100% duty cycle simply means the compressor will deliver a consistent CFM and PSI the entire time the compressor is in use, which is different than being able to run continuously. A piston-type compressor eventually needs to stop and cool down even if they are rated at 100% duty cycle.