Turn the air compressor switch to “ON,” restarting your air compressor. Measuring the amps that your air compressor produces while in use can be done one of three ways at the breaker box, exposing the wires at the compressor or using a splitter between the outlet and the cord of the compressor. If you plugged the compressor into another outlet and the breaker did not trip, or you measured the amperage draw during use and the beakers ratings are above that witch the compressor is drawing, chances are the breaker is weak or there is a loose wire in that circuit.

This page will provide you with the reasons as to why your air compressor keeps tripping its circuit breaker as well as providing you with existing reader problems and responses. If your air compressor circuit breaker trips and you check your air filter and it is dirty, replace it and try again! If your compressor still trips, you will need to troubleshoot further. The key difference between an air compressor blowing the circuit breaker and the motor thermal overload switch is that the latter is solely due to the compressor motor overheating, and so, the thermal overload triggers and doesn’t allow the compressor to turn on until it has sufficiently cooled.

When the air compressor tank is drained down to the cut in pressure level, the pressure switch reacts to the drop in tank pressure, it trips to “Passing” and the compressor should start and run until the compressor tank pressure has reached the normal cut out pressure setting, at which time the compressor should stop and wait for the tank air pressure to drop to the cut in pressure level again. If for some reason the motor cannot start, it will continue to draw power, and may pull enough amperage to exceed the capacity of breaker or fuse and as a result the compressor trips the breaker or fuse on restart. If the compressor starts easily again, then it’s pretty much certain that it’s the air compressor unloader valve failure that is causing your air compressor to trip the breaker on restart.

In this article, I will be writing about some of the ways to troubleshoot a tripping circuit breaker so you can know when the circuit breaker is the reason your air compressor is not starting. A dirty air filter is one of the reasons circuit breakers in air compressor trips. Another reason the circuit breaker in your air compressor trips too often is if it is faulty.

Most air compressors have a built-in circuit breaker that performs these functions to protect the air pump and compressor. When an air compressor has a dirty air filter, the air compressor motor has to work harder than it normally would have to. The most common reason why an air compressor keeps tripping the circuit breaker is a failed start capacitor.

Motors can draw 6-8 times there normal full load current when starting. Breakers work don’t tripp the instant the current is more than 20.1 amps. First check if the Unloader is working on the compressor.

If you have multiple devices plugged into the same circuit, turning on your air compressor may simply put it over the edge – air compressors tend to draw a lot of power when the motor starts up. It’s typically more common for an air compressor to trip the breaker after running for a short time or as the motor kicks on a second time to maintain pressure in the air tank. As you can see, there are numerous reasons your air compressor might be tripping the breaker.

why air compressor trips breaker Related Question:

How do I stop my air compressor from tripping the breaker?

Sometimes on new compressors, the easiest way to cure this concern would be to move the compressor to a dedicated circuit large enough to handle the load. Moving the compressor may also identify a week breaker. If the breaker trips on one 15 amp breaker but not the other, The tripped one may be old and worn.

Why is my AC compressor tripping the breaker?

If your air conditioner fan motor is tripping the breaker because it’s not getting enough power from your circuit, then a broken coil fan may be to blame. Broken or missing parts of an ac unit can cause this issue that results in higher electricity usage and possible breakers trips.

Can a bad compressor cause breaker to trip?

Old or weak compressor A weak compressor has trouble starting. When it does try to start, it may try to pull too much electricity, which will trip your breaker. If this is the problem, an air conditioning professional might recommend installing a hard start kit.

Where is the unloader valve on an air compressor?

Where Is the Unloader Valve Located? If you own a smaller reciprocating air compressor, you’ll likely find the unloader valve mounted on or inside the pressure switch. When the switch shuts the compressor off, it actuates the valve.

What happens when AC compressor goes bad?

When your ac compressor fails, less air will come out from the vents, the air coming out could be warm, and the system may continually run without actually cooling your home. This is because refrigerant isn’t pumped through the system, and it can result in a higher power bill.

Why does my AC compressor stop after a few minutes?

If there’s something wrong with your air conditioner that makes it shut off after just 15 minutes, it’s usually one of these issues: Unit is overheating: This often means there is simply a buildup of grime inside the compressor unit, but it could also mean there’s a refrigerant leak or another problem.

Can you fix a grounded compressor?

Just to answer your literal question, compressors are not field serviceable. If your compressor has a problem, the only option is to replace it. Final result: the compressor is just fine. The first tech didn’t bother to examine the whip, which was shorted phase-to-phase just as it exited the disconnect box.

What is the most common cause of compressor failure?

Low Refrigerant Levels — Low refrigerant levels are typically caused by leaks in the refrigerant lines. Low refrigerant levels make the compressor work hard just to pump enough refrigerant through the AC unit, which, as you may have guessed, can lead to compressor failure.

How long does it take for compressor overload to reset?

(If power is available at the compressor terminals, and no amp draw is shown, the internal overload may be open due to overheat, the unit must be cooled for the overload to reset.) This may take up to 24 hours.

Do air compressors have a reset button?

To reset your reciprocating air compressor, allow time for the compressor to cool down and then push the reset button before attempting to turn the unit on again.

What causes a circuit breaker to burn?

Overheating is the most common cause of circuit breaker burns. This occurs due to overloads, power surges, or arc-faults in your system. Any of these events will overheat your circuit suddenly, possibly causing the breaker to heat up and burn, thus resulting in a tripped circuit breaker.

What would cause a heat pump to trip the breaker?

When your heat pump’s condenser coils get dirty, the unit has to work at a higher capacity to produce the same amount of heating or cooling. Subsequently, this can produce an overload, which trips the circuit breaker. To avoid this, be sure to schedule maintenance at least once a year.

How do you know if your air compressor unloader is bad?

You can have two problems. Air leaking from an “unloader” valve on the pressure switch continuously (after the motor shuts off) is an indication of a leaking tank check valve, not a bad pressure switch. Air leaking from the unloader while the motor is running is an indication of a bad unloader valve.

How do you know if your unloader valve is bad?

Water leaks and inconsistent behavior are also signs of a potential failure in the near future. González: The typical signal when there is an unloader malfunction is a reduction of flow through the nozzle, which results in pressure loss. Dean: Typical symptom of an unloader failure is a sudden smooth pressure loss.

What does an air compressor unloader valve do?

An air compressor unloader valve is a device used by air compressors to release the trapped air inside the compression chamber and tank discharge line when the motor stops. This allows the motor to start up easier.