The following air compressor troubleshooting tips can help solve some of the most common problems that are known to occur with air compressors. If you shut down the compressor when the tank is filled with air and then find that the pressure gauge is showing a drop in pressure, you know that the compressor is leaking air. If you plug in the compressor, the pressure switch response to the air leak and dropping compressor pressure will be to start the compressor again.

The check valve prevents tank air from back flowing to the pump. To test the check valve, let the air compressor fill the tank until the pump shuts off. The pull the ring on the safety valve to bleed air from the tank to reach the cut-in pressure, so the pressure switch tires to restart the motor to refill the air tank.

This is especially important considering that the safety valve opens to relieve excess air pressure in the case that the pressure switch fails to turn off the compressor at the cut-out pressure setting. The most common reason behind a reciprocating compressor’s inability to reach sufficient pressure is a defective reed valve – which can exhaust air out from the air inlet on single stage models or, through the intercooler safety valve in the case of a defective reed valve on a two-stage piston compressor instead of passing it through the intercooler, through the second stage piston, and out through the discharge. Effective pump rings seal the air in the cylinders, prevent excess oil from passing downstream, and are critical in ensuring an air compressor’s ability to build pressure – if pump rings are worn, the pump will be unable to effectively compress air which can greatly reduce the volume of air the pump can produce.

Keep on reading to go to the 10 quickest fixes for an air compressor that won’t stop running. Check out these 10 fixes for an air compressor that won’t stop running. We’re sure that these 10 fixes for an air compressor motor that won’t stop running will get your air compressor back up and running.

why won’t my air compressor run Related Question:

What would cause an air compressor to not turn on?

The first and most obvious thing to do when your compressor won’t start is to make sure that the unit is receiving power. It is always possible that a fuse has been blown or that a breaker has been tripped. If such issues occur regularly, you should have an electrician take a look.

How do you reset an air compressor?

To reset your reciprocating air compressor, allow time for the compressor to cool down and then push the reset button before attempting to turn the unit on again.

How do I get my air compressor to kick on?

Setting the cut-out pressure Turn clockwise to increase (if you want a higher maximum pressure) or count-clockwise to decrease (if you want a lower maximum pressure. Open the drain valve and wait until the pressure drops low enough to start the compressor. Close the drain valve.

Does an air compressor have a fuse?

Blown Fuse or Tripped Breaker Some air compressors have reset switches while others will have in-line fuses that need to be checked. To find them follow the line of power from the air compressor back to the outlet. If you find a blown fuse or tripped breaker go ahead and either replace the fuse or reset the breaker.

Is there a reset button on AC compressor?

Most air conditioning units are equipped with a reset button. These buttons tend to be red and quite small. If you’re having a tough time finding it, consult your owner’s manual. (If you can’t find it, most are published online for quick reference).

How long does it take an AC compressor to reset?

After you’ve turned the system back on, it will take a bit of time for the air conditioner’s internal circuitry to reset. It usually takes about 30 minutes, so sit tight until then. 5. Switch on the AC system at the thermostat.

Can you reset a motor?

Once the motor has cooled sufficiently it can be re-started, usually by pushing the popped-out reset switch back down. If the motor turns off again on re-set you should not keep running it as it may be damaged and the system may be unsafe.

How does an air compressor pressure switch work?

When the specified system pressure is reached, a diaphragm inside the pressure switch pushes against a mechanism which forces the electrical contacts apart, breaking the circuit and stopping the motor. At the same time, the pressure relief valve opens and relieves back-pressure caught between the pump and check valve.

Can I bypass the pressure switch on a air compressor?

Simply put a jumper wire across the contacts of the pressure switch. It will then run without stopping. Be sure that the safety valve on the pressure vessle is operating, and large enough to vent the entire capacity of the compressor.

Can you fix a pressure switch?

Because it gets so much constant use, the pressure switch is the most common failure point for a well pump. Fortunately, it is also easy to repair and replace.

How do you tell if a compressor is burnt out?

But perhaps the simplest method is the “odor test.” The smell that comes when a hose is connected to the system is both pungent and revealing. Once sniffed, it’s never forgotten and is one of the best indicators of a compressor burn-out.